How sensitive is Ninja 5 heatsink to airflow changes?

How we were testing

The original fans are quite slow, so it was especially fascinating to watch how the heatsink behaved with settings that are not intended for it – with a proper airflow through the ribs. Not only with both fans, but also with just one. Some results really surprised us. And the temperatures in the passive mode are very interesting too, one of the reasons why Ninja coolers have such a good reputation.

Bonus tests of coolers are a regular extension of standard reviews. In addition to cooling efficiency around the socket, they include testing and comparison of heatsinks using the same fans, as well as fully passive operation without any active cooling. And also other various tests that might be interesting for a particular cooler.

How we were testing

During the tests, we also measured CPU MOSFETs heating at 33 and 39 dBA. We put the sensor right into the heatsink. These tests always begin with the same starting temperature (35 °C). Although Gigabyte is known for an excellent cooling of its power supply and manages to maintain very attractive temperatures, it is still easy to determine which of the coolers more or less keeps doing a good job cooling the critical components.

The fans were aligned in such a way that they do not exceed over the top rib because it would be pointless there. It is more important to swirl the air in the lower parts. This was still measured with the default fans.

In the next phase of the tests, the original fans were replaced by the reference fans to create the performance comparison of the heatsinks with the same fans. These results might come in handy when you want to replace the default fans. Usually because they are too fast or too slow (and inefficient), or they produce disturbing sounds, or for whatever reason based on personal preferences.

Optimal candidates for such tests are the “industrial” Noctua NF-F12 iPPC fans. Thanks to their wide range, we could test with a very high flow and at a very low noise level. We increased the flow of the system fans (4× 1200 rpm) only in 24 V mode (2000 rpm without any problems). For a better comparison, we also included the tests with standard 4× 550 rpm. After reducing the voltage to 15 V, the fans were relatively quiet (1290 rpm) and at 9 volts they were running at 765 rpm only, which could be especially challenging for large two-tower heatsinks and larger liquid coolers. We replaced the reference fans with the number corresponding to the original set. Usually one or two. For a better orientation, it is marked in the charts (1/2 ×).

   

Finally, the coolers competed with each other without a fan. The processor we used was Core i7-5930K (TDP 140 W) with Vcore 0.9 V, which had 25 W lower power consumption than with default settings. These tests took longer than those before, 900 seconds. Most coolers cannot handle this. After 95 ºC, tests were interrupted and considered unsuccessful. Therefore, temperatures in idle are also interesting. We used traditional configuration of system cooling and airflow.

Extra test: Configuration with one fan only. It’s an atypical setting for the fifth model, but all previous Ninjas (standard versions) were supplied with just one fan. Is the final effect of two fans the same as on the paper?


  •  
  •  
  •  
Flattr this!

Test: MSI Z890 Ace (and CU9 285K) with CoreLiquid I360 cooler

What would be the results of standard motherboard tests if we used the MSI MAG CoreLiquid I360 cooler with them? Better. Specifically, lower temperatures would be achieved for the CPU cores, which would then run at higher clock speeds, which naturally means higher computing performance. Not dramatically, but if we are to illustrate the situation with plates of scales, their position is quite clear. Read more “Test: MSI Z890 Ace (and CU9 285K) with CoreLiquid I360 cooler” »

  •  
  •  
  •  

Endorfy Fortis 5 Black ARGB: (Quite) a bit of light in the dark

With the Fortis 5 Black ARGB cooler, it’s not enough to just note that it has a backlit fan compared to the Fortis 5 Black. There are more specifics that shape its characteristics. It’s not visible on the external features, because the stated parameters are the same as those of the non-ARGB model, but we’ve come across a few differences when dissecting the results. And we can certainly write about remarkable differences that are worth reflecting on. Read more “Endorfy Fortis 5 Black ARGB: (Quite) a bit of light in the dark” »

  •  
  •  
  •  

Endorfy Fortis 5 Black: Six heatpipes for Intel CPUs

In addition to the standard variant, the Fortis 5 is also available in a completely black version. Compared to the lower-end series (Fera 5), it has two more heatpipes which increase the cooling performance of this cooler. In practice, however, it only does better in some cases. When the processor can benefit from the “extra material” available in the Fortis 5 cooler. How so? We’ll break everything down in this detailed analysis. Read more “Endorfy Fortis 5 Black: Six heatpipes for Intel CPUs” »

  •  
  •  
  •  

Comments (5) Add comment

  1. This test is hard to read. Why are some graphs empty? What is @24V? Is it 2x 12V or do you actually put 24V through the fans?

    1. Sorry for late reply. Passive cooling mean that heatsink haven’t a fan on its ribs but the system cooling is active.

Leave a Reply

Your email address will not be published. Required fields are marked *